1. Kauntungan: volume cilik, kapasitas pecah dhuwur, busur cendhak, anti getaran
2. Iki minangka produk sing ideal kanggo panggunaan darat lan segara
3. Setelan parameter sing cukup
4. Desain aksesoris kothak, instalasi gampang
5. Ukuran Kompak
• Suhu: ora luwih saka +40°C, lan ora luwih murah tinimbang -5°C, lan suhu rata-rata ora luwih saka +35°C
• Lokasi instalasi ora luwih saka 2000m
• Kelembapan relatif: ora luwih saka 50%, nalika Suhu +40°C. Produk iki bisa tahan kelembapan sing luwih dhuwur ing suhu sing luwih endhek, contone, nalika suhu ing +20°C, produk iki bisa tahan kelembapan relatif 90%. Kondensasi sing kedadeyan amarga owah-owahan suhu kudu digatekake kanthi pangukuran khusus.
• Kelas polusi: Kelas 3
• Sudut miring instalasi maksimal: 22,5°
• Jinis instalasi sirkuit bantu lan sirkuit kontrol: Kelas II; Jinis instalasi pemutus sirkuit utama: Kelas III
• Bisa tahan getaran normal lan beroperasi kanthi stabil ing kahanan laut
| Nomer Model | Ukuran pigura sing dirating saiki Inm A | Arus sing dirating In (A) | Tegangan kerja sing dirating Ue (V) | Wong Polandia | Pemutus sirkuit cendhak sing dirating (kA) | Jarak busur (mm) | |||
| Icu/ cosφ | Ics/ cos Φ | ||||||||
| 400V | 690V | 400V | 690V | ||||||
| RDM1-80L | 80 | (6), 10, 16, 20, 25, 32, 40, 50, 63, 80 | 400 | 3 | 25 | - | 12.5 | - | ≤50 |
| RDM1-80M | 400 | 3, 4 | 50 | - | 25 | - | |||
| RDM1-125L | 125 | (10), 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 | 400 | 2, 3, 4 | 35 | - | 20 | - | ≤50 |
| RDM1-125M | 400/690 | 2, 3, 4 | 50 | 10 | 35 | 5 | |||
| RDM1-125H | 400/690 | 3, 4 | 85 | 20 | 50 | 10 | |||
| RDM1-250L | 250 | 100, 125, 160, 180, 200, 225, 250 | 400 | 2, 3, 4 | 35 | - | 25 | - | ≤50 |
| RDM1-250M | 400/690 | 2, 3, 4 | 50 | 10 | 35 | 5 | |||
| RDM1-250H | 400/690 | 3, 4 | 85 | 10 | 50 | 5 | |||
| RDM1-400L | 400 | 250, 315, 350, 400 | 400/690 | 3, 4 | 50 | 10 | 35 | 5 | ≤100 |
| RDM1-400M | 400/690 | 3, 4 | 65 | 10 | 42 | 5 | |||
| RDM1-400H | 400/690 | 3, 4 | 85 | 10 | 50 | 5 | |||
| RDM1-630L | 630 | 400, 500, 630 | 400 | 3, 4 | 35 | - | 25 | - | ≤100 |
| RDM1-630M | 400/690 | 3, 4 | 50 | 10 | 35 | 5 | |||
| RDM1-630H | 400 | 3, 4 | 85 | - | 50 | - | |||
| RDM1-800M | 800 | 630, 700, 800 | 4400/690 | 3, 4 | 50 | 20 | 35 | 10 | ≤100 |
| RDM1-800H | 400 | 3, 4 | 85 | - | 50 | - | |||
| RDM1-1250M | 1250 | 700, 800, 1000, 1250 | 400/690 | 3, 4 | 65 | 20 | 35 | 10 | ≤100 |
| RDM1-1250M | 1600 | 1250, 1600 | 400/690 | 3, 4 | 65 | 20 | 35 | 10 | ≤100 |
| 4P kanthi jinis N-pole | |
| Kode | Katrangan struktur (Produksi tanpa dituduhake yaiku jinis B) |
| Jinis | Kutub-N tanpa overload tripping, lan kutub-N tansah nyambung |
| Tipe B | Kutub-N tanpa overload trip, lan nyambungake, pedhot karo kutub liyane |
| Pemutus sirkuit distribusi | Pemutus sirkuit proteksi motor | ||||||
| Arus sing dirating ln (A) | Rilis relay termal | Arus operasional pelepasan elektromagnetik (A) | Arus sing dirating ln (A) | Rilis relay termal | Arus operasional pelepasan elektromagnetik (A) | ||
| 1.05ln Wektu non-tripping konvensional H (kahanan adhem) | 1.30ln Wektu tripping konvensional H (kahanan panas) | 1.0ln Wektu non-trip konvensional H (kahanan adhem) | 1.2ln Wektu tripping konvensional H (kahanan panas) | ||||
| 10≤ln≤80 | 1 | 1 | 10ln±20% | 10≤ln≤630 | 2 | 2 | 12ln±20% |
| 80 | 2 | 2 | |||||
| 125 | 2 | 2 | 5ln±20%, 10ln±20% | ||||
Pelepasan shunt
Diagram sambungan, deleng Gambar 1 lan Gambar 2.
Tegangan terukur saka catu daya kontrol: AC 50/60Hz, 230V, 400V; DC24v, pemutus sirkuit bisa beroperasi kanthi andal ing sangisore 85% nganti 110% saka tegangan catu daya kontrol terukur.
Cathetan: Katrangan babagan simbol K ing Gambar 2
K: Pelepasan shunt
Saklar mikro sing disambungake seri karo koil internal minangka kontak sing biasane ditutup. Nalika pemutus sirkuit dibukak, kontak kasebut mbukak dhewe lan nutup nalika ditutup.
Pelepasan voltase kurang
Nalika voltase kurang saka 35% saka voltase daya kontrol sing dirating, pelepasan iki bisa nyegah pemutus sirkuit supaya ora nutup. Diagram kabel, deleng Gambar 3.
Nalika voltase mudhun nganti kisaran 70% nganti 35% saka voltase daya kontrol sing dirating, pelepasan voltase sing kurang bakal trip.
Nalika voltase ana ing kisaran 85% nganti 110% saka voltase daya kontrol sing dirating, pelepasan iki bisa njamin sirkuit nutup kanthi andal.
Kabar:Pemutus sirkuit kanthi pelepas voltase kurang bisa trip lan nutup, mung nyuplai pemutus sirkuit kanthi voltase terukur.
Kontak bantu
Kontak alarm
Parameter voltase operasional sing dirating, delengen Tabel 1.
| Jinis (tabel 1) | Arus sing dirating ukuran pigura | Arus pemanasan konvensional A | AC-15 | DC-13 | |||
| Tegangan operasional sing dirating (V) | Frekuensi sing dirating (Hz) | Arus sing dirating (A) | Tegangan operasional sing dirating (V) | Arus sing dirating (A) | |||
| Kontak bantu | Inm≤250 | 3 | 400 | 50 | 0.3 | 230 | 0.15 |
| Inm≥400 | 3 | 0.4 | 0.15 | ||||
| Kontak sing nguwatirake | 80≤Inm≤800 | 3 | 0.3 | 0.15 | |||
Aksesoris pemutus sirkuit khusus Meter sing dikontrol biaya
Nilai voltase operasional saka pelepasan shunt meter sing dikontrol biaya yaiku Ac230V 50Hz, beroperasi ing kisaran 65% nganti 110% Ue, nalika kontak NC K saka meter sing dikontrol biaya dicopot amarga tunggakan, pemutus sirkuit bakal telat 0,5-2 detik. Diagram kabel kaya ing ngisor iki:
Cathetan:Kontak normal tertutup saka meter energi listrik prabayar K
Pemutus sirkuit tegangan berlebih
Pemutus sirkuit voltase sing luwih dhuwur kudune rusak ing kahanan ing ngisor iki:
a) Nalika voltase operasional sing dirating (voltase fase) Ue luwih murah tinimbang 262v
b) Nalika garis netral saka telung fase lan papat kabel pedhot
c) Nalika garis netral salah nyambungake garis fase
Struktur mekanisme operasi listrik deleng Tabel ing ngisor iki
| Jinis/Model | RDM1-80,125,250 | RDM1-400,630,800 |
| Struktur | Elektromagnet | Motor |
| Spesifikasi | 50Hz, 230V. 400V | 50Hz, AC110~230V, DC110~230V |
Cathetan: Sawise pemutus sirkuit karo mekanisme operasi listrik mati, mekanisme operasi listrik kudu nggawe pemutus sirkuit matigesper maneh sadurunge bisa ditutup.
Mekanisme operasi manual kudu dipasang sawise ngebor bolongan miturut diagram
Gagang putar "OFF" dituduhake ing posisi horisontal, jaga posisi tangan, lan coba operasikake gagang, rotasi kudu fleksibel, lan pemutus sirkuit kudu mbukak nalika gagang ing posisi horisontal; lan pemutus sirkuit kudu ditutup nalika gagang ing posisi vertikal.
| Nomer Model | RDM1-80 | RDM1-125 | RDM1-250 | RDM1-400 | RDM1-630 | RDM1-800 |
| Dimensi instalasi | 50 | 52 | 54 | 97 | 97 | 90 |
| Nilai Y saka gagang operasi relatif marang Pusat pemutus | 0 | 0 | 0 | 0 | 0 | 0 |
Dimensi instalasi saka interlock mekanik saka rong pemutus sirkuit, deleng Gambar 6 lan Tabel 2
| Nomer Model (Tabel 2) | A | B | W | C | D | L | Φd |
| RDM1-80 | 25 | 117 | 105 | 35 | 22 | 117 | 3.5 |
| RDM1-125 | 30 | 129 | 120 | 46 | 22 | 140 | 4.5 |
| RDM1-250 | 35 | 126 | 138 | 46 | 22 | 132 | 5.5 |
| RDM1-400L,M,H | 44 | 194 | 178.5 | 56 | 28 | 188 | 7 |
| RDM1-630 | 58 | 200 | 230 | 56 | 28 | 240 | 7 |
| RDM1-800 | 70 | 243 | 250 | 56 | 28 | 252 | 7.5 |
Kabel ngarep sakabèhé lan dimensi bolongan papan instalasi RDM1-80~800A, deleng Gambar 12, Gambar 8 lan tabel3
| Nomer Model (Tabel 3) | Sambungan ngarep sakabèhé | Dimensi instalasi | ||||||||||||||||||||
| W | L | H | H1 | H2 | H3 | W1 | L1 | L2 | W2 | K | N | M | X | Y | A | B | Φd | |||||
| 3P | 4P | 3P | 4P | 3P | 4P | 3P | 4P | |||||||||||||||
| RDM1-80L | 78 | - | 135 | 73 | 90.5 | 20 | 6.5 | 25 | 170 | 117 | 14 | 86.5 | 42.5 | 35 | - | 25 | - | 69 | - | 25 | 117 | 4 |
| RDM1-80M RDM1-80H | 78 | 102 | 135 | 82 | 98.5 | 28 | 6.5 | 25 | 170 | 117 | 14 | 86.5 | 41.5 | 35 | 26.5 | 25 | 23 | 69 | 49 | 25 | 117 | 4 |
| RDM1-125L | 92 | 122 | 150 | 68 | 86 | 24 | 7.5 | 30 | 200 | 132 | 17 | 89 | 43 | 32 | 27 | 27 | 23 | 67 | 51 | 30 | 129 | 4 |
| RDM1-125M RDM1-125H | 92 | 122 | 150 | 86 | 104 | 24 | 7.5 | 30 | 200 | 132 | 17 | 89 | 43 | 32 | 27 | 27 | 23 | 67 | 51 | 30 | 129 | 4 |
| RDM1-250L | 107 | 142 | 165 | 86 | 110 | 24 | 6 | 35 | 230 | 144 | 24 | 98 | 51 | 39 | 27 | 27 | 23 | 80 | 54 | 35 | 126 | 5 |
| RDM1-250M RDM1-250H | 107 | 142 | 165 | 103 | 127 | 24 | 6 | 35 | 230 | 144 | 24 | 102 | 51 | 39 | 27 | 27 | 23 | 80 | 54 | 35 | 126 | 5 |
| RDM1-400L | 150 | 198 | 257 | 107 | 155 | 38 | 5 | 48 | 357 | 224 | 31 | 128 | 64.5 | 48 | 48 | 66 | 66 | 90 | 90 | 44 | 194 | 7 |
| RDM1-400M RDM1-400H | 150 | 198 | 257 | 107 | 155 | 38 | 5 | 48 | 357 | 224 | 31 | 128 | 64.5 | 48 | 48 | 66 | 66 | 90 | 90 | 44 | 194 | 7 |
| RDM1-630L | 182 | 240 | 270 | 112 | 160 | 45 | 3.5 | 58 | 370 | 234 | 41 | 135 | 67.5 | 45 | 45 | 66 | 66 | 90 | 90 | 58 | 200 | 7 |
| RDM1-630M RDM1-630H | 182 | 240 | 270 | 112 | 160 | 43 | 3.5 | 58 | 370 | 234 | 41 | 138 | 67.5 | 45 | 45 | 66 | 66 | 90 | 90 | 58 | 200 | 7 |
| RDM1-800M RDM1-800H | 210 | 280 | 280 | 117 | 160 | 42 | 5 | 70 | 380 | 243 | 44 | 136 | 65.5 | 48 | 48 | 67 | 67 | 82 | 82 | 70 | 243 | 7.5 |
Dimensi sakabèhé kabel mburi, deleng Gambar 8 lan Tabel 4
Dimensi bolongan-bukaan instalasi kabel mburi, deleng Gambar 9
| Nomer Model (Tabel 4) | Kode dimensi. | |||||||||
| H3 | H4 | D | W | L2 | Φd2 | A | B | C | Φd1 | |
| RDM1-80 | 28 | 46 | M5 | 25 | 117 | 8 | 25 | 117 | 50 | 5.5 |
| RDM1-125 | 64 | 100 | M8 | 30 | 132 | 24 | 30 | 108 | 60 | 5.5 |
| RDM1-250 | 70 | 100 | M10 | 35 | 144 | 26 | 35 | 122 | 70 | 5.5 |
| RDM1-400 | 46 | 83 | Φ12 | 48 | 224 | 32 | 44 | 194 | 94 | 7 |
| RDM1-630 | 45 | 85 | Φ16 | 58 | 234 | 37 | 58 | 200 | 116 | 7 |
| RDM1-800 | 47 | 87 | Φ16 | 70 | 243 | 48 | 70 | 243 | 70 | 7.5 |
Jinis plug-in RDM1 sakabèhé lan dimensi bolongan instalasi, deleng Gambar 10, Gambar 11 lan Tabel 5
Dimensi sakabèhé pemutus sirkuit jinis plug-in RDM1-80~630 lan dimensi bolongan-bukaan papan instalasi
| Dicocogake MCCB (Tabel 5) | Kode dimensi. | |||||||||||||||
| A | B1 | B2 | C1 | C2 | E | F | G | K | M | N | H | H1 | AM | BM | 4-dina | |
| RDM1-80 | 135 | 75 | 100 | 50 | 75 | 60 | 117 | 100 | 17.5 | 16 | 9 | 27.5 | 17.5 | M5 | M5 | Φ5.5 |
| RDM1-125 | 168 | 91 | 125 | 60 | 90 | 56 | 132 | 92 | 38 | 32.5 | 18 | 48 | 32.5 | M6 | M8 | Φ6.5 |
| RDM1-250 | 186 | 107 | 145 | 70 | 105 | 54 | 144 | 94 | 45.5 | 34 | 15 | 49.5 | 33.5 | M6 | M8 | Φ6.5 |
| RDM1-400 | 280 | 149 | 200 | 60 | 108 | 129 | 224 | 170 | 55 | 44 | 23.5 | 59.5 | 40 | M8 | M12 | Φ8.5 |
| RDM1-630 | 300 | 182 | 242 | 100 | 158 | 123 | 234 | 170 | 65 | 50 | 30.5 | 60 | 40 | M8 | M12 | Φ8.5 |
| RDM1-800 | 305 | 210 | 280 | 90 | 162 | 146 | 242 | 181 | 62 | - | - | 87 | 60 | M10 | M14 | Φ11 |
Dhuwure pemutus sirkuit RDM1 sawise masang mekanisme operasi motor, delengen Tabel 6
| Dhuwur/Nomer Model (Tabel 6) | RDM1-80L | RDM1-80M | RDM1-125L | RDM1-125M RDM1-125H | RDM1-250L | RDM1-250M RDM1-250H |
| AC | 155 | 164 | 152 | 170 | 182 | 199 |
| DC | 160 | 171 | 153 | 171 | 177 | 194 |
| Dhuwur/Nomer Model | RDM1-400L,M,H | RDM1-630L | RDM1-630M RDM1-630H | RDM1-800M RDM1-800H |
| DC | 246 | 262 | 262 | 252 |
Parameter teknis utama
4.1 Parameter teknis utama deleng Tabel 3
| Nomer Model | Ukuran pigura sing dirating saiki Inm A | Arus sing dirating In (A) | Tegangan kerja sing dirating Ue (V) | Wong Polandia | Pemutus sirkuit cendhak sing dirating (kA) | ||||
| Icu/ cosφ | Ics/ cos Φ | ||||||||
| 400V | 690V | 400V | 690V | ||||||
| RDM1-63L | 63 | (6), 10, 16, 20, 25, 32, 40, 50, 63 | 400 | 3 | 25 | - | 12.5 | - | ≤50 |
| RDM1-63M | 400 | 3, 4 | 50 | - | 25 | - | |||
| RDM1-63H | 400 | 3 | 50 | - | 25 | - | |||
| RDM1-125L | 125 | (10), 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 | 400 | 2, 3, 4 | 35 | - | 25 | - | ≤50 |
| RDM1-125M | 400/690 | 2, 3, 4 | 50 | 10 | 35 | 5 | |||
| RDM1-125H | 400/690 | 3, 4 | 85 | 20 | 50 | 10 | |||
| RDM1-250L | 250 | 100, 125, 160, 180, 200, 225, 250 | 400 | 2, 3, 4 | 35 | - | 25 | - | ≤50 |
| RDM1-250M | 400/690 | 2, 3, 4 | 50 | 10 | 35 | 5 | |||
| RDM1-250H | 400/690 | 3, 4 | 85 | 10 | 50 | 5 | |||
| RDM1-400C | 400 | 225, 250, 315, 350, 400 | 400 | 3 | 50 | - | 35 | - | ≤100 |
| RDM1-400L | 400/690 | 3, 4 | 50 | 10 | 35 | 5 | |||
| RDM1-400M | 400/690 | 3, 4 | 65 | 10 | 42 | 5 | |||
| RDM1-400H | 400/690 | 3, 4 | 100 | 10 | 65 | 5 | |||
| RDM1-630L | 630 | 400, 500, 630 | 400 | 3, 4 | 50 | - | 25 | - | ≤100 |
| RDM1-630M | 400/690 | 3, 4 | 65 | 10 | 32.5 | 5 | |||
| RDM1-630H | 400 | 3, 4 | 100 | - | 60 | - | |||
| RDM1-800M | 800 | 630, 700, 800 | 4400/690 | 3, 4 | 75 | 20 | 50 | 10 | ≤100 |
| RDM1-800H | 400 | 3, 4 | 100 | - | 65 | - | |||
| RDM1-1250M | 1250 | 700, 800, 1000, 1250 | 400/690 | 3, 4 | 65 | 20 | 35 | 10 | ≤100 |
4.2 Pelepasan arus kelebihan beban kasusun saka pelepasan relai termal kanthi karakteristik wektu terbalik lan pelepasan sesaat (elektromagnetik).
| Pemutus sirkuit distribusi | Pemutus sirkuit proteksi motor | ||||||
| Arus sing dirating ln (A) | Rilis relay termal | Arus operasional pelepasan elektromagnetik (A) | Arus sing dirating ln (A) | Rilis relay termal | Arus operasional pelepasan elektromagnetik (A) | ||
| 1.05 Ing wektu non-trip konvensional H (kahanan adhem) | 1.30 Ing wektu tripping konvensional H (kahanan panas) | 1.0 Ing wektu non-trip konvensional H (kahanan adhem) | 1.2 Ing wektu tripping konvensional H (kahanan panas) | ||||
| 10≤ln≤63 | 1 | 1 | 10ln±20% | 10≤ln≤630 | 2 | 2 | 12ln±20% |
| 63 | 2 | 2 | |||||
| 100 | 2 | 2 | 5ln±20%, 10ln±20% | ||||
Aksesoris pemutus sirkuit
5.1 Aksesoris njero
5.1.1 Pelepasan shunt
Diagram sambungan, deleng Gambar 1 lan Gambar 2.
Tegangan sing dirating saka catu daya kontrol: AC 50/60Hz, 230V, 400V; DC24V, pemutus sirkuit bisa beroperasi kanthi andal ing sangisore 85% nganti 110% saka tegangan catu daya kontrol sing dirating.
5.12 Pelepasan voltase kurang
Nalika voltase kurang saka 35% saka voltase daya kontrol sing dirating, pelepasan iki bisa nyegah pemutus sirkuit supaya ora nutup. Diagram sambungan, deleng Gambar 3.
Nalika voltase mudhun nganti kisaran 70% nganti 35% saka voltase daya kontrol sing dirating, pelepasan voltase sing kurang bakal trip.
Nalika voltase ana ing kisaran 85% nganti 110% saka voltase daya kontrol sing dirating, rilis iki bisa njamin dosis sirkuit kanthi andal.
Kabar: Pemutus sirkuit kanthi pelepas voltase kurang bisa trip lan nutup, mung nyedhiyakake pemutus sirkuit kanthi voltase terukur.
5.13 Kontak bantu
Pemutus sirkuit duwé rong set kontak, saben set ora mbukak ing listrik, rincian kontak tambahan, deleng Tabel 5.
5.14 Kontak alarm
Parameter voltase operasional sing dirating, delengen Tabel 5.
| Tipe | Ukuran pigura sing dirating saiki Inm A | AC-15 | DC-13 | ||||
| Arus pemanasan konvensional A | Tegangan operasional sing dirating V | Frekuensi Ratwd Hz | Arus sing dirating A | Tegangan operasional sing dirating V | Arus sing dirating A | ||
| Kontak bantu | lnm≤250 | 3 | 400 | 50 | 0.3 | 230 | 0.15 |
| Inm≥2400 | 3 | 0.4 | 0.15 | ||||
| Kontak alarm | 63≤lnm≤800 | 3 | 0.3 | 0.15 | |||
5.15 Aksesoris pemutus sirkuit khusus saka meter prabayar
Pelepasan shunt saka voltase operasional sing dirating Meter Prabayar yaiku AC230V 50Hz, Operasine ing kisaran 65% nganti 110% Ue, nalika titik Ctrl mbukak, pemutus sirkuit bakal pedhot sawise wektu tundha 0,5 nganti 2 detik. Deleng Diagram:
5.16 Pemutus sirkuit tegangan berlebih
Pemutus sirkuit voltase sing luwih dhuwur kudune rusak ing kahanan ing ngisor iki:
a) Nalika voltase operasional sing dirating (voltase fase) luwih murah tinimbang 262V
b) Nalika garis netral saka telung fase lan papat kabel pedhot
c) Nalika garis netral salah nyambungake garis fase,
5.2 pemutus sirkuit aksesoris ekstranal
5.21 Struktur mekanisme operasi listrik deleng Tabel 6
| Model | RDM 1-63, 100, 2 50 | RDM 1-400,630,800 | |||||
| Tipe | |||||||
| Struktur | Elektromagnetisme | Motor | |||||
| Spesifikasi | 50Hz, 230V, 400V | ||||||
5.22 Mekanisme operasi manual kudu dipasang sawise ngebor bolongan miturut diagram.
Gagang putar "OFF" dituduhake ing posisi horisontal, jaga posisi gagang, lan coba operasikake gagang, rotasi kudu fleksibel, lan pemutus sirkuit kudu mbukak nalika gagang ing posisi horisontal; lan pemutus sirkuit kudu ditutup nalika gagang ing posisi vertikal.
| Nomer Model | RDM1-63 | RDM1-100 | RDM1-250 | RDM 1-400 | RDM 1-630 | RDM 1-800 | ||
| Dimensi instalasi | 50 | 52 | 54 | 97 | 97 | 90 | ||
| Nilai Y saka gagang operasi relatif marang Pusat pemutus | 0 | 0 | 0 | 0 | 0 | 0 | ||
Ukuran sakabèhé lan pemasangan (mm)
5.23 Dimensi instalasi interlock mekanik saka rong pemutus sirkuit, delengen Tabel 6 Gambar 6 lan Tabel 8.
| Nomer Model | A | B | W | C | L | A | Φd |
| RDM 1-63 | 25 | 117 | 105 | 35 | 22 | 117 | 3.5 |
| RDM1-125 | 30 | 129 | 120 | 46 | 22 | 140 | 4.5 |
| RDM1-250 | 35 | 126 | 138 | 46 | 22 | 132 | 5.5 |
| RDM1-400L, M, H | 44 | 194 | 178.5 | 56 | 28 | 188 | 7 |
| RDM 1-800 | 44 | 215 | 176 | 56 | 28 | 188 | 5.5 |
| RDM 1-630 | 58 | 200 | 230 | 56 | 28 | 240 | 7 |
| RDM1-400C | 70 | 243 | 250 | 56 | 28 | 252 | 5.5 |
| Nomer Model | Sambungan ngarep sakabèhé | Dimensi instalasi | ||||||||||||||||||||
| W | L | H | H1 | H2 | H3 | W1 | L1 | L2 | W2 | K | N | M | X | Y | A | B | Φd | |||||
| 3P | 4P | 3P | 4P | 3P | 4P | 3P | 4P | |||||||||||||||
| RDM1-63L | 76 | - | 135 | 73 | 90.5 | 20 | 6.5 | 25 | 170 | 117 | 14 | 86.5 | 42.5 | 35 | - | 25 | 0 | 69 | - | 25 | 117 | 4 |
| RDM1-63M RDM1-63H | 76 | 102 | 135 | 82 | 98.5 | 28 | 6.5 | 25 | 170 | 117 | 14 | 86.5 | 41.5 | 35 | 26.5 | 25 | 23 | 69 | 49 | 25 | 117 | 4 |
| RDM1-125L | 92 | 122 | 150 | 68 | 86 | 24 | 7.5 | 30 | 200 | 132 | 17 | 89 | 43 | 32 | 27 | 27 | 23 | 67 | 51 | 30 | 129 | 4 |
| RDM1-125M | 92 | 122 | 150 | 86 | 104 | 24 | 7.5 | 30 | 200 | 132 | 17 | 89 | 43 | 32 | 27 | 27 | 23 | 67 | 51 | 30 | 129 | 4 |
| RDM1-125H | ||||||||||||||||||||||
| RDM1-250L | 107 | 142 | 165 | 86 | 110 | 24 | 6 | 35 | 230 | 144 | 24 | 98 | 51 | 39 | 27 | 27 | 23 | 80 | 54 | 35 | 126 | 5 |
| RDM1-250M | 107 | 142 | 165 | 103 | 127 | 24 | 6 | 35 | 230 | 144 | 24 | 102 | 51 | 39 | 27 | 27 | 23 | 80 | 54 | 35 | 126 | 5 |
| RDM1-250H | ||||||||||||||||||||||
| RDM1-400C | 140 | - | 257 | 100 | 146 | 36.5 | 7.5 | 44 | 361.5 | 225 | - | 128 | 50.5 | 20 | - | 53 | - | 90 | - | 44 | 215 | 6.5 |
| RDM1-400L | 150 | 198 | 257 | 107 | 155 | 38 | 5 | 48 | 357 | 224 | 31 | 128 | 64.5 | 48 | 48 | 66 | 66 | 90 | 90 | 44 | 194 | 7 |
| RDM1-400M | 150 | 198 | 257 | 107 | 155 | 38 | 5 | 48 | 357 | 224 | 31 | 128 | 64.5 | 48 | 48 | 66 | 66 | 90 | 90 | 44 | 194 | 7 |
| RDM1-400H | ||||||||||||||||||||||
| RDM1-630L | 182 | 240 | 270 | 112 | 160 | 45 | 3.5 | 58 | 370 | 234 | 41 | 135 | 67.5 | 45 | 45 | 66 | 66 | 90 | 90 | 58 | 200 | 7 |
| RDM1-630M RDM1-630H | 182 | 240 | 270 | 114 | 160 | 43 | 3.5 | 58 | 370 | 234 | 41 | 138 | 69 | 45 | 42.5 | 69 | 67 | 96 | 90 | 58 | 200 | 7 |
| RDM1-800M RDM1-800H | 210 | 280 | 280 | 117 | 160 | 42 | 5 | 70 | 380 | 243 | 44 | 136 | 65.5 | 48 | 48 | 67 | 67 | 82 | 82 | 70 | 243 | 7.5 |
6.2 Dimensi sakabèhé sambungan mburi, delengen Gambar 8 lan Tabel 10.
6.3 Dimensi bolongan mbukak instalasi sambungan mburi, deleng Tabel 9
| Nomer Model | Kode dimensi. | |||||||||
| H3 | H4 | D | W | L2 | Φd2 | A | B | C | Φd1 | |
| RDM 1-63 | 28 | 46 | M5 | 25 | 117 | 8 | 25 | 117 | 50 | 5.5 |
| RDM1-125 | 64 | 100 | M8 | 30 | 132 | 24 | 30 | 129 | 60 | 5.5 |
| RDM1-250 | 70 | 100 | MIO | 35 | 144 | 26 | 35 | 126 | 70 | 5.5 |
| RDM 1-400 | 71 | 105.5 | Φ12 | 48 | 224 | 32 | 44 | 194 | 94 | 7 |
| RDM1-400C | 71 | 105.5 | Φ16 | 44 | 225 | 32 | 44 | 215 | - | 8.5 |
| RDM 1-630 | 46 | 105 | Φ16 | 58 | 234 | 37 | 58 | 200 | 116 | 7 |
| RDM 1-800 | 105 | 105 | 70 | 243 | 48 | 70 | 243 | 70 | 7.5 | |
6.4 Jinis RDM1 Insert sakabèhé lan dimensi bolongan mbukak instalasi, deleng Gambar 10, Gambar 11 lan Tabel 11
| Nomer Model | Kode dimensi. | ||||||||||||||
| A | B1 | B2 | C1 | C2 | E | F | G | K | H | H1 | H2 | AM | BM | 4-dina | |
| RDM 1-63 | 135 | 75 | 100 | 50 | 75 | 60 | 1 17 | 100 | 17.5 | 27.5 | 18 | 16 | M5 | M5 | Φ5.5 |
| RDM1-125 | 168 | 91 | 125 | 60 | 90 | 56 | 132 | 92 | 38 | 50 | 33 | 28 | M6 | M8 | Φ6.5 |
| RDM 1-250 | 186 | 107 | 145 | 70 | 105 | 54 | 145 | 94 | 46 | 50 | 33 | 37 | M6 | M8 | Φ6.5 |
| RDM 1-400 | 280 | 149 | 200 | 60 | 108 | 129 | 224 | 170 | 55 | 60 | 38 | 46 | M8 | M12 | Φ8.5 |
| RDM 1-630 | 280 | 144 | 88 | - | 143 | 224 | 180 | 50 | 60 | 38 | 48 | M8 | M12 | Φ9 | |
| RDM 1-800 | 300 | 182 | 242 | 100 | 158 | 123 | 234 | 170 | 65 | 60 | 39 | 50 | M8 | M12 | Φ8.5 |
| RDM1-400C | 305 | 210 | 280 | 90 | 162 | 146 | 242 | 181 | 62 | 87 | 60 | 22 | M10 | M14 | Φ11 |
Dhuwure pemutus sirkuit RDM1 6.5 sawise masang mekanisme operasi motop, delengen Tabel 12.
| Nomer Model | RDM1-65L | RDM1-63M RDM1-63H | RDM1-100L | RDM1-100M RDM1-100H | RDM 1-255L | RDM1-25OM RDM1-25OH |
| Dhuwur | ||||||
| AC | 155 | 164 | 152 | 170 | 182 | 199 |
| DC | 160 | 171 | 153 | 171 | 177 | 194 |
| Nomer Mod. | RDM 1-400C | RDM1-400L. M. H. | RDM1-63OL | RDM1-630M RDM1-630H | RDM1-800M RDM1-800H |
| Dhuwur | |||||
| AC | 227 | 238 | 246 | 246 | 247 |
| DC | 160 | 255 | 262 | 262 | 261 |