Seri RDC5 (Kontaktor AC)

Kontaktor AC seri RDC5 dirancang utamane kanggo sirkuit AC kanthi frekuensi 50Hz utawa 60Hz, kanthi voltase maksimal 690V lan arus maksimal 95A. Iki digunakake kanggo nguripake lan mateni sirkuit saka jarak jauh, lan uga bisa diintegrasi langsung karo relay termal kanggo mbentuk starter elektromagnetik, sing berfungsi kanggo nglindhungi sirkuit sing rawan operasi overload. Kajaba iku, kontaktor bisa dipasang aksesoris kalebu grup kontak bantu tipe blok, kontak tunda udara, mekanisme interlock mekanik, lan liya-liyane kanggo nggabungake kontaktor tunda, kontaktor arah, lan starter star-delta.

Produk iki tundhuk karo standar EC/EN60947-4-1.


  • Seri RDC5 (Kontaktor AC)
  • Seri RDC5 (Kontaktor AC)
  • Seri RDC5 (Kontaktor AC)
  • Seri RDC5 (Kontaktor AC)
  • Seri RDC5 (Kontaktor AC)
  • Seri RDC5 (Kontaktor AC)

Rincian Produk

Parameter

Conto & Struktur

Dimensi

Kondisi Operasi Normal lan Kondisi Pemasangan

1. Suhu sekitar: +5℃~+40℃, suhu rata-rata sajrone 24 jam ora ngluwihi +35℃

2. Dhuwur: ora ngluwihi 2000m

3. Kahanan atmosfer: nalika suhu paling dhuwur yaiku +40℃, kelembapan relatif ora ngluwihi 50%; bisa ngidini kelembapan relatif dhuwur nalika suhu relatif kurang, contone, tekan 90% nalika suhu +20℃, kudu diukur nalika ana kondensasi amarga variasi suhu.

4. Tingkat polusi: 3

5. Kategori instalasi: Ⅲ

6. Posisi instalasi: gradien permukaan pemasangan menyang permukaan vertikal ora ngluwihi ±5°

7. Dampak lan getaran: produk kudu dipasang lan digunakake ing panggonan sing ora ana goyangan, dampak lan getaran sing jelas.

Parameter Teknis Utama

Parameter teknik utama kontaktor kanggo ndeleng tabel 1

Model Produk (Tabel 1) RDC5-06 RDC5-09 RDC5-12 RDC5-18 RDC5-25 RDC5-32 RDC5-38 RDC5-40 RDC5-50 RDC5-65 RDC5-80 RDC5-95
Cacahing tiang 3 tiang
Tegangan insulasi sing dirating (Ui)V 690
Tegangan operasi sing dirating (Ue)V 380/400,660/690
Arus pemanasan konvensional (Ith)A 16 20 20 25 32 40 40 50 60 80 110 110
Arus sing dirating (Ie)A AC-3 380/400V 6 9 12 18 25 32 38 40 50 65 80 95
660/690V 3.8 6.6 8.9 12 18 22 22 34 39 42 49 49
AC-4 380/400V 2.6 3.5 5 7.7 8.5 12 14 18.5 24 28 37 44
660/690V 1 1.5 2 3.8 4.4 7.5 8.9 9 12 14 17.3 21.3
Daya Terukur (Pe)kW AC-3 380/400V 2.2 4 5.5 7.5 11 15 18.5 18.5 22 30 37 45
660/690V 3 5.5 7.5 10 15 18.8 18.5 30 33 37 45 45
AC-4 380/400V 1.1 1.5 2.2 3.3 4 5.4 5.5 7.5 11 15 18.5 22
660/690V 0.75 1.1 1.5 3 3.7 5.5 6 7.5 10 11 15 18.5
Umur mekanik (10000 kali/jam) 1200 1000 900 650
Urip listrik AC-3 (10000 kali/jam) 110 90 65
AC-4 (10000 kali/jam) 22 22 17 11
Frekuensi operasi AC-3 (kaping/jam) 1200 600
AC-4 (kaping/jam) 300
Koil Tegangan kontrol langka Us(V) AC 24,36,48,110,127,220/230,240,380/400,415,440
Tegangan tarik 50/60HZ V (0.85~1.1) Kita
Tegangan rilis 50/60Hz V (0.2~0.7) Kita
Konsumsi daya koil VA sing ditarik 50 60 70 200 200
Tahan VA 6~9 6~9.5 6~9.5 15~20 15~20
Daya W 1~3 1~3 1~3 6~10 6~10
Terminal Potongan mm² 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2
Kawat fleksibel kanthi terminal mm² 4 2.5 4 2.5 4 2.5 4 2.5 6 4 6 4 6 4 25 10 25 10 25 10 50 16 50 16
Kawat fleksibel tanpa terminal mm² 4 4 4 4 4 4 4 4 6 6 6 6 6 6 25 16 25 16 25 16 50 25 50 25
Kawat atos mm² 4 4 4 4 4 4 6 6 6 6 10 6 10 6 25 10 25 10 25 10 50 25 50 25
Torsi pengencangan (N•m) 1.2 1.8 5 9
Jenis sekering sing cocog Model RDT16(NT)-00
Arus sing dirating (A) 16 20 20 32 40 50 63 63 80 80 100 125
Relay termal sing cocog RDR5-25 RDR5-25 RDR5-25 RDR5-25 RDR5-25 RDR5-25
RDR5-36
RDR5-25
RDR5-36
RDR5-93 RDR5-93 RDR5-93 RDR5-93 RDR5-93
Kontak bantu Bisa ditambahake karo kontak tambahan F4, LA8, kontak tunda udara tipe LA2-D/LA3-D

Dimensi

32d6ac9edca539e2d4ca6ee03d444337
Model (Tabel 2) Amax Bmax B1max B2max Cmax C1max C2max
RDC5-06, 09, 12, 18 74.5 45.5 58 71 82.5 114.5 139.5
RDC5-25, 32, 38 83 56.5 69 82 97 129 154
RDC5-40, 50, 65 127.5 74.5 88 101 117 148.5 173.5
RDC5-80, 95 127.5 85.5 99 112 125.5 157 182
Cathetan: B1maks=kontaktor+1×LA8; B2maks=kontaktor+2× LA8; C1maks=kontaktor+F4; C2maks=kontaktor+LA2(3)D
Model (Tabel 3) a b c d e f
RDC5-06, 09, 12, 18 35 50/60 - - - -
RDC5-25, 32, 38 40 50/60 - - - -
RDC5-40, 50, 65 - - 105 40 100/110 59
RDC5-80, 95 - - 105 40 100/110 67

Model Produk

RDC5-06

RDC5-09

RDC5-12

RDC5-18

RDC5-25

RDC5-32

RDC5-38

RDC5-40

RDC5-50

RDC5-65

RDC5-80

RDC5-95

Cacahing tiang

3 tiang

Tegangan insulasi sing dirating (Ui)V

690

Tegangan operasi sing dirating (Ue)V

380/400, 660/690

Arus pemanasan konvensional (Ith)A

16

20

20

25

32

40

40

50

60

80

110

 

110

 

Arus sing dirating (le)A

AC-3

380/400V

6

9

12

18

25

32

38

40

50

65

80

95

660/690V

3.8

6.6

8.9

12

18

22

22

34

39

42

49

49

AC-4

380/400V

2.6

3.5

5

7.7

8.5

12

14

18.5

24

28

37

44

660/690V

1

1.5

2

3.8

4.4

7.5

8.9

9

12

14

17.3

21.3

Daya Terukur (PE) KW

AC-3

380/400V

2.2

4

5.5

7.5

11

15

18.5

18.5

22

30

37

45

660/690V

3

5.5

7.5

10

15

18.8

18.5

30

33

37

45

45

AC-4

380/400V

1.1

1.5

2.2

3.3

4

5.4

5.5

7.5

11

15

18.5

22

660/690V

0.75

1.1

1.5

3

3.7

5.5

6

7.5

10

11

15

18.5

Umur mekanik (10000 kali/jam)

1200

1000

900

650

Urip listrik

AC-3 (10000 kali/jam)

110

90

65

AC-4 (10000 kali/jam)

22

22

17

11

Frekuensi operasi

AC-3 (kaping/jam)

1200

600

AC-4 (kaping/jam)

300

Koil

Tegangan kontrol langka Us(V)

AC 24,36,48,110,127,220/230,240,380/400,415,440

Tegangan tarik 50/60HZ V

(0.85-1.1) Kita

Tegangan rilis 50/60Hz V

(0.2-0.7) Kita

Konsumsi daya koil

VA sing ditarik

50

60

70

200

200

Tahan VA

6-9

6-9.5

6-9.5

15-20

15-20

Daya W

1-3

1-3

1-3

6-10

6-10

Potongan mm²

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

Terminal

Kawat fleksibel kanthi terminal mm²

4

2.5

4

2.5

4

2.5

4

2.5

6

4

6

4

6

4

25

10

25

10

25

10

50

16

50

16

Kawat fleksibel tanpa terminal mm²

4

4

4

4

4

4

4

4

6

6

6

6

6

6

25

16

25

16

25

16

50

25

50

25

Kawat atos mm²

4

4

4

4

4

4

6

6

6

6

10

6

10

6

25

10

25

10

25

10

50

25

50

25

Torsi pengencangan

(N*m)

1.2

1.8

5

9

Jenis sekering sing cocog

Model

RDT16(NT)-00

Arus sing dirating (A)

16

20

20

32

40

50

63

63

80

80

100

 

125

 

Relay termal sing cocog

RDR5-25

RDR5-25

RDR5-25

RDR5-25

RDR5-25

RDR5-25 RDR5-36

RDR5-25 RDR5-36

RDR5-93

RDR5-93

RDR5-93

RDR5-93

RDR5-93

Kontak bantu

Bisa ditambahake karo kontak tambahan F4, LA8, kontak tunda udara tipe LA-D/LA3-D

24

Nomer Model

6

 

 

10:32A lan ngisor, 3 kutub + 1NO kontak tambahan
01:32A lan ngisor, 3 kutub + 1NC kontak bantu
11:40A lan ndhuwur, 3 kutub + 1NO + 1NC kontak tambahan
004:25A lan ngisor, 4NO kontak utama
008:25A lan ngisor, 2NO + 2NC kontak utama

Arus operasi sing dirating

Kontaktor AC

26

Model Amax Bmax B1max B2max Cmax C1max C2max
RDC5-06,09,12,18 74.5 45.5 58 71 82.5 114.5 139.5
RDC5-25,32,38 83 56.5 69 82 97 129 154
RDC5-40,50,65 127.5 74.5 88 101 117 148.5 173.5
RDC5-80.95 127.5 85.5 99 112 125.5 157 182
Cathetan: B1maks=kontaktor+LA8; B2maks=kontaktor+2×LA8; C1maks=kontaktor+F4; C2maks=kontaktor+LA2(3)D
Model a b c d e f
RDC5-06,09,12,18 35 50/60 - - - -
RDC5-25,32,38 40 50/60 - - - -
RDC5-40,50,65 - - 105 40 100/110 59
RDC5-80.95 - - 105 40 100/110 67

Kondisi operasi normal lan kondisi instalasi

3.1 Suhu sekitar: +5℃~+40℃ suhu rata-rata sajrone 24 jam ora ngluwihi +35℃

3.2 Dhuwur: ora ngluwihi 2000m

3.3 Kahanan atmosfer: nalika suhu paling dhuwur +40℃, kelembapan relatif ora ngluwihi 50%; bisa ngidini kelembapan sing relatif dhuwur nalika suhu relatif kurang, kanggo

contone. tekan 90% nalika ana ing +20 kudune ngukur nalika ana

kondensasi kedadeyan amarga variasi suhu.

3.4 Tingkat polusi: 3

3.5 Kategori instalasi

3.6 Posisi instalasi: aradien saka permukaan gunung menyang permukaan vertikal ora ngluwihi +5°

3.7. Efek lan getaran: produk kudu dipasang lan digunakake ing panggonan sing ora ana guncangan lan getaran sing jelas.

  • Tulis pesenmu ing kene lan kirim menyang kita