Rincian Produk:
Pemutus sirkuit arus sisa seri RDM5L (RCCB) digunakake kanggo jaringan distribusi daya AC50/60Hz, kanthi voltase operasi sing dirating nganti 400V, arus operasi sing dirating nganti 800A. RCCB nduweni proteksi sentuhan ora langsung kanggo manungsa, lan nglindhungi piranti saka bebaya geni sing disebabake dening kerusakan insulasi lan gangguan pentanahan. Lan uga bisa nyebarake energi listrik, nglindhungi sirkuit lan catu daya saka overdosis lan korsleting. Lan uga kanggo nransfer sirkuit lan miwiti motor. Standar: EC60947-2
Parameter:
| Ukuran pigura arus sing dirating lnm(A) | 125 | 250 | 400 | 800 | ||||||||||||||
| Arus sing dirating In(A) | 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 | 100, 125, 160, 180, 200, 225, 250 | 200, 225, 250, 315, 350, 400 | 400,500,630,700,800 | ||||||||||||||
| Tiang | 3P, 4P | |||||||||||||||||
| Frekuensi sing dirating (Hz) | 50, 60 | |||||||||||||||||
| Tegangan insulasi sing dirating Ui(V) | AC1000 | |||||||||||||||||
| Tegangan tahan impuls sing dirating Uimp (V) | 8000 | |||||||||||||||||
| Tegangan operasi sing dirating Ue(V) | AC400 | |||||||||||||||||
| Jarak busur (mm) | ≤50 | ≤100 | ||||||||||||||||
| Tingkat kapasitas pemutus sirkuit cendhak | L | M | H | L | M | H | L | M | H | L | M | H | ||||||
| Kapasitas pemutus sirkuit cendhak paling dhuwur sing dirating lcu(kA) | 35 | 50 | 85 | 35 | 50 | 85 | 50 | 65 | 100 | 50 | 70 | 100 | ||||||
| Kapasitas pemutus sirkuit cendhak sing dirating lcs (kA) | 25 | 35 | 50 | 25 | 35 | 50 | 25 | 35 | 50 | 25 | 35 | 50 | ||||||
| Arus tahan wektu cendhak sing dirating lcw (kA/0.5s) | 一 | 5 | 8 | |||||||||||||||
| Nggunakake Tipe | A | |||||||||||||||||
| Arus operasi residual sing dirating I?n(mA) | 300, 100300 (Ora ana wektu tundha) 100, 300, 500 (Waktu tundha) | 100,300,500 | 100,300,500 | 300, 500, 1000 | ||||||||||||||
| Arus non-operasi residual sing dirating 1?no(mA) | 0.5l△n | |||||||||||||||||
| Kapasitas pemutus sirkuit cendhak residual sing dirating l?m(kA) | 0.25lcu | |||||||||||||||||
| Wektu operasi arus sisa | Ora ana wektu tundha | 0.3s | ||||||||||||||||
| Telat | 0.4s, 1.0s | |||||||||||||||||
| Tipe operasi arus sisa | Tipe AC | |||||||||||||||||
| Standar | IEC60947-2 GB14048.2 GB/Z6829 | |||||||||||||||||
| Suhu sekitar | -35℃~+70℃ | |||||||||||||||||
| Urip listrik | 8000 | 8000 | 7500 | 7500 | ||||||||||||||
| Urip mekanik | 20000 | 20000 | 10000 | 10000 | ||||||||||||||
| Pelepasan undervoltage | ■ | ■ | ■ | ■ | ||||||||||||||
| Pelepasan shunt | ■ | ■ | ■ | ■ | ||||||||||||||
| Kontak alarm | ■ | ■ | ■ | ■ | ||||||||||||||
| Kontak bantu | ■ | ■ | ■ | ■ | ||||||||||||||
Dimensi![]() (mm) | W | 92(3P) | 107(3P) | 150 (3P) | 210(3P) | |||||||||||||
| 122(4P) | 142(4P) | 198(4P) | 280(4P) | |||||||||||||||
| L | 150 | 165 | 257 | 280 | ||||||||||||||
| H1 | 110 | 115 | 148 | 168 | ||||||||||||||
| H2 | 96 | 94 | 115 | 122 | ||||||||||||||
Wektu kiriman: 30 Mei 2025