RDX6-63DC Series 6KA MCB

RDX6-63 / DC MCB cocok kanggo sirkuit distribusi DC saka AC 50/60Hz, voltase dirating nganti 400V, dirating saiki nganti 63A, dirating short-circuit breaking kapasitas ora ngluwihi 6000A, minangka nggunakake sirkuit kang arang nyambungake, breaking lan ngoper, kanthi fungsi overload, proteksi short-circuit.Kangge, wis modul fungsi tambahan kuwat, kayata kontak tambahan, kontak karo pratondo nguwatirake, shunt ngeculake, ing-voltase ngeculake, lan remot release kontrol etc. modul.Produk iki ngonfirmasi standar GB10963.1 lan IEC60898-1.


  • RDX6-63DC Series 6KA MCB
  • RDX6-63DC Series 6KA MCB
  • RDX6-63DC Series 6KA MCB

Detail Produk

Aplikasi

Paramèter

Sampel & Struktur

ukuran

Pambuka produk

RDX6-63 / DC MCB cocok kanggo sirkuit distribusi DC saka AC 50/60Hz, voltase dirating nganti 400V, dirating saiki nganti 63A, dirating short-circuit breaking kapasitas ora ngluwihi 6000A, minangka nggunakake sirkuit kang arang nyambungake, breaking lan ngoper, kanthi fungsi overload, proteksi short-circuit.Kangge, wis modul fungsi tambahan kuwat, kayata kontak tambahan, kontak karo pratondo nguwatirake, shunt ngeculake, ing-voltase ngeculake, lan remot release kontrol etc. modul.Produk iki ngonfirmasi standar GB10963.1 lan IEC60898-1.

RDX6-63 / DC MCB cocok kanggo sirkuit distribusi DC saka AC 50/60Hz, voltase dirating nganti 400V, dirating saiki nganti 63A, dirating short-circuit breaking kapasitas ora ngluwihi 6000A, minangka nggunakake sirkuit kang arang nyambungake, breaking lan ngoper, kanthi fungsi overload, proteksi short-circuit.Kangge, wis modul fungsi tambahan kuwat, kayata kontak tambahan, kontak karo pratondo nguwatirake, shunt ngeculake, ing-voltase ngeculake, lan remot release kontrol etc. modul.

Klasifikasi

1. Jumlah kutub: 1P, 2P
2. Ngeculake karakteristik: Tipe C
3. Dirating saiki: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63A
4. Rated voltase operasi: 220V / 440V

Kondisi operasi normal lan kahanan instalasi

1. Suhu sekitar: -5 ℃ ~ + 40 ℃, suhu rata-rata ing 24h ora
ora ngluwihi +35 ℃;
2. Dhuwur panggonan instalasi: ora ngluwihi 2000m;
3. Kelembapan relatif ora ngluwihi 50% nalika ana ing suhu paling dhuwur saka
+40 ℃, lan diijini asor relatif dhuwur nalika ing relatif kurang
suhu, contone, tekan 90% nalika iku ing 20 ℃.Iku kudu njupuk
pangukuran nalika ana kondensasi ing prodhuk amarga saka
variasi suhu.
4. Tingkat polusi: 2
5. kondisi Instalasi: iku kudu diinstal ing panggonan tanpa ketok
impact lan geter uga medium tanpa bebaya (bledosan).
6. Mode instalasi: nganggo rel instalasi TH35-7.5
7. Kategori instalasi: II, III

Model No.

10

Parameter teknik utama

Karakteristik ngeculake saiki kudu dikonfirmasi ing tabel 1 nalika pemutus sirkuit ana ing kondisi instalasi normal lan suhu dhasar 30-35 ℃.

Ora. Tipe tripping Rated saiki Ing Tes saiki A Kira-kira wektu asil samesthine Negara wiwitan
1 C Kabeh nilai 1.13 Ing t≤1h Ora ngeculake kahanan kadhemen
2 C Kabeh nilai 1.45 Ing t≤1h Ngeculake sanalika sawise test nomer serial 1
3 C ≤32A 2.55 Ing 1s <t<60s Ngeculake kahanan kadhemen
32A<Ing≤63A 1s <t <120s
4 C Kabeh nilai 5 Ing (AC) t≤0.1s Ora ngeculake kahanan kadhemen
7 Ing (DC)
5 C Kabeh nilai 10 Ing (AC) t≤0.1s Ngeculake kahanan kadhemen
15 Ing (DC)
Tipe tripping Rated saiki A Kapasitas putus hubung singkat A Konstanta wektu T
C 1≤Ing≤63 6 000 4ms

RDX6-63DC 1 RDX6-63DC 2 RDX6-63DC 3

Wangun lan dimensi instalasi

11

RDX6-63 / DC MCB cocok kanggo sirkuit distribusi DC saka AC 50/60Hz, voltase dirating nganti 400V, dirating saiki nganti 63A, dirating short-circuit breaking kapasitas ora ngluwihi 6000A, minangka nggunakake sirkuit kang arang nyambungake, breaking lan ngoper, kanthi fungsi overload, proteksi short-circuit.Kangge, wis modul fungsi tambahan kuwat, kayata kontak tambahan, kontak karo pratondo nguwatirake, shunt ngeculake, ing-voltase ngeculake, lan remot release kontrol etc. modul.

Klasifikasi

1. Jumlah kutub: 1P, 2P
2. Ngeculake karakteristik: Tipe C
3. Dirating saiki: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63A
4. Rated voltase operasi: 220V / 440V

Kondisi operasi normal lan kahanan instalasi

1. Suhu sekitar: -5 ℃ ~ + 40 ℃, suhu rata-rata ing 24h ora
ora ngluwihi +35 ℃;
2. Dhuwur panggonan instalasi: ora ngluwihi 2000m;
3. Kelembapan relatif ora ngluwihi 50% nalika ana ing suhu paling dhuwur saka
+40 ℃, lan diijini asor relatif dhuwur nalika ing relatif kurang
suhu, contone, tekan 90% nalika iku ing 20 ℃.Iku kudu njupuk
pangukuran nalika ana kondensasi ing prodhuk amarga saka
variasi suhu.
4. Tingkat polusi: 2
5. kondisi Instalasi: iku kudu diinstal ing panggonan tanpa ketok
impact lan geter uga medium tanpa bebaya (bledosan).
6. Mode instalasi: nganggo rel instalasi TH35-7.5
7. Kategori instalasi: II, III

Model No.

10

Parameter teknik utama

Karakteristik ngeculake saiki kudu dikonfirmasi ing tabel 1 nalika pemutus sirkuit ana ing kondisi instalasi normal lan suhu dhasar 30-35 ℃.

Ora. Tipe tripping Rated saiki Ing Tes saiki A Kira-kira wektu asil samesthine Negara wiwitan
1 C Kabeh nilai 1.13 Ing t≤1h Ora ngeculake kahanan kadhemen
2 C Kabeh nilai 1.45 Ing t≤1h Ngeculake sanalika sawise test nomer serial 1
3 C ≤32A 2.55 Ing 1s <t<60s Ngeculake kahanan kadhemen
32A<Ing≤63A 1s <t <120s
4 C Kabeh nilai 5 Ing (AC) t≤0.1s Ora ngeculake kahanan kadhemen
7 Ing (DC)
5 C Kabeh nilai 10 Ing (AC) t≤0.1s Ngeculake kahanan kadhemen
15 Ing (DC)
Tipe tripping Rated saiki A Kapasitas putus hubung singkat A Konstanta wektu T
C 1≤Ing≤63 6 000 4ms

RDX6-63DC 1 RDX6-63DC 2 RDX6-63DC 3

Wangun lan dimensi instalasi

11

Tulis pesen ing kene lan kirimake menyang kita