RDQH5 seri Automatic Transfer Ngalih (ATS) Applied kanggo Power-sistem AC50 / 60Hz, Rated operate voltase 400V, Rated operate saiki saka 16A nganti 630A.Normal, Serep interline produk bisa nyambung karo Net-grid utawa siji karo Net-grid lan liyane karo generator power-supply.Nalika salah siji baris duwe fault (phase-mundhut, overvoltage, undervoltage), ATS ngalih sirkuit liyane menyang baris kanthi otomatis kanggo nyimpen daya-supply.Iki ditrapake utamane ing papan sing penting, kayata bangunan dhuwur, mall, bank, rumah sakit, pesawat, lan liya-liyane, sing ora diidini mati.Lan ATS nduweni short-circuit, proteksi kakehan kanggo njamin linuwih lan safety saka sumber daya.
Standar: IEC/EN 60947-6-1, GB/T 14048.11
RDQH5 | 125 | L | 4P | R | |||||
Model NO. | Ukuran Frame | Tipe Breaker | Pole | Tipe Kontrol | |||||
Transfer otomatis Ngalih (ATS) | Kode 125 250 400 630 | L: Tipe L Circuit breaker M: Tipe M Circuit breaker H: Tipe H Circuit breaker | 3p: 3 kutub 4p:4 pku | R: nyembur dhewe lan ngreset dhewe S: nyopir dhewe lan dhewe ora ngreset T: Saling Backup |
Cathetan: Grid Net-Generator mung nduweni mode kerja kanggo mbuwang lan ngreset dhewe
Fungsi Kontrol
Set Fungsi | Setel Range | Default |
1 Mode Operasi | Auto, Manual | Auto |
2 Struktur Grid | Grid Net lan Grid Net, Grid Net lan Generator Power | Grid Net lan Grid Net |
3 Mode kerja | Self throw-self reset, Self throw-self not reset, Mutual backup | Self uncalan-Self reset |
4 Weker weker | MURUP MATI | ON |
5 Fungsi Monitor | Overvoltage, Undervoltage, deteksi phase-loss.Setel sawetara ambang overvoltage 230V ~ 280V, Undervoltage 140V ~ 220VO | Vervoltage set 270V, Undervoltage se 170V |
6 Normal dadi Serep Wektu-tundha | 1s~255s | 3s |
7 Gawe serep dadi wektu tundha Normal | 1s~255s | 3s |
8 Loro-lorone break tundha | 0.5s~10s | 3s |
9 Deteksi urutan fase | MURUP MATI | ON |
10 Kontrol sambungan geni | AC / DC12V ~ 36V input kanggo loro break | |
11 Kalibrasi voltase | Bisa njupuk 6 cara Kalibrasi Tegangan |
Parameter teknis
Ukuran Bingkai Rated Inm Saiki (A) | 125 | 250 | 400 | 630 | ||||||||
Rated saiki Ie(A) | 16, 20, 25, 32, 40 | 100, 125, 160, 180 | 225, 250, 315, | 400,500,630 | ||||||||
50, 63, 80, 100, 125 | 200, 225, 250 | 350, 400 | ||||||||||
Pole | 3p,4p | |||||||||||
F requency (Hz) | 50 | |||||||||||
Tegangan isolasi terukur Ui (V) | AC800 | |||||||||||
Rated impuls tahan tegangan Uimp(kV) | 8 | |||||||||||
Tegangan operasi Rated Ue (V) | AC400 | |||||||||||
Tipe Breaker | L | M | H | L | M | H | L | M | H | L | M | H |
Kapasitas putus hubung singkat Icn (kA) | 35 | 50 | 85 | 35 | 50 | 85 | 50 | 65 | 100 | 50 | 65 | 100 |
Kapasitas koneksi hubung singkat Icm (kA) | 73.5 | 105 | 187 | 73.5 | 105 | 187 | 105 | 143 | 220 | 105 | 143 | 220 |
Tipe ATSE | Tipe CB | |||||||||||
Nggunakake Tipe | AC-33iB | |||||||||||
Suhu sekitar | -35°C~+70°C | |||||||||||
Urip Listrik (Times) | 1000 | 1000 | 1000 | 1000 | ||||||||
Umur mekanik (Times) | 5000 | 5000 | 3000 | 2000 | ||||||||
Wektu transfer mini | ≤3s (Bisa ditambahake wektu tundha konversi) |
Ukuran Bentuk
Model NO. | L (mm) | W (mm) | H (mm) |
RDQH5- 125L/3P | 308 | 194 | 132 |
RDQH5- 125L/4P | 338 | 194 | 132 |
RDQH5- 125M(H)/3P | 308 | 194 | 149 |
RDQH5- 125M(H)/4P | 338 | 194 | 149 |
RDQH5-250L/3P | 347 | 209 | 151 |
RDQH5-250L/4P | 382 | 209 | 151 |
RDQH5-250M(H)/3P | 347 | 209 | 169 |
RDQH5-250M(H)/4P | 382 | 209 | 169 |
RDQH5-400L/3P | 490 | 309 | 215 |
RDQH5-400L/4P | 539.5 | 309 | 215 |
RDQH5-630L/3P | 568 | 328 | 216.5 |
RDQH5-630L/4P | 626 | 328 | 216.5 |
Fungsi Kontrol
Set Fungsi | Setel Range | Default |
1 Mode Operasi | Auto, Manual | Auto |
2 Struktur Grid | Grid Net lan Grid Net, Grid Net lan Generator Power | Grid Net lan Grid Net |
3 Mode kerja | Self throw-self reset, Self throw-self not reset, Mutual backup | Self uncalan-Self reset |
4 Weker weker | MURUP MATI | ON |
5 Fungsi Monitor | Overvoltage, Undervoltage, deteksi phase-loss.Setel sawetara ambang overvoltage 230V ~ 280V, Undervoltage 140V ~ 220VO | Vervoltage set 270V, Undervoltage se 170V |
6 Normal dadi Serep Wektu-tundha | 1s~255s | 3s |
7 Gawe serep dadi wektu tundha Normal | 1s~255s | 3s |
8 Loro-lorone break tundha | 0.5s~10s | 3s |
9 Deteksi urutan fase | MURUP MATI | ON |
10 Kontrol sambungan geni | AC / DC12V ~ 36V input kanggo loro break | |
11 Kalibrasi voltase | Bisa njupuk 6 cara Kalibrasi Tegangan |
Parameter teknis
Ukuran Bingkai Rated Inm Saiki (A) | 125 | 250 | 400 | 630 | ||||||||
Rated saiki Ie(A) | 16, 20, 25, 32, 40 | 100, 125, 160, 180 | 225, 250, 315, | 400,500,630 | ||||||||
50, 63, 80, 100, 125 | 200, 225, 250 | 350, 400 | ||||||||||
Pole | 3p,4p | |||||||||||
F requency (Hz) | 50 | |||||||||||
Tegangan isolasi terukur Ui (V) | AC800 | |||||||||||
Rated impuls tahan tegangan Uimp(kV) | 8 | |||||||||||
Tegangan operasi Rated Ue (V) | AC400 | |||||||||||
Tipe Breaker | L | M | H | L | M | H | L | M | H | L | M | H |
Kapasitas putus hubung singkat Icn (kA) | 35 | 50 | 85 | 35 | 50 | 85 | 50 | 65 | 100 | 50 | 65 | 100 |
Kapasitas koneksi hubung singkat Icm (kA) | 73.5 | 105 | 187 | 73.5 | 105 | 187 | 105 | 143 | 220 | 105 | 143 | 220 |
Tipe ATSE | Tipe CB | |||||||||||
Nggunakake Tipe | AC-33iB | |||||||||||
Suhu sekitar | -35°C~+70°C | |||||||||||
Urip Listrik (Times) | 1000 | 1000 | 1000 | 1000 | ||||||||
Umur mekanik (Times) | 5000 | 5000 | 3000 | 2000 | ||||||||
Wektu transfer mini | ≤3s (Bisa ditambahake wektu tundha konversi) |
Ukuran Bentuk
Model NO. | L (mm) | W (mm) | H (mm) |
RDQH5- 125L/3P | 308 | 194 | 132 |
RDQH5- 125L/4P | 338 | 194 | 132 |
RDQH5- 125M(H)/3P | 308 | 194 | 149 |
RDQH5- 125M(H)/4P | 338 | 194 | 149 |
RDQH5-250L/3P | 347 | 209 | 151 |
RDQH5-250L/4P | 382 | 209 | 151 |
RDQH5-250M(H)/3P | 347 | 209 | 169 |
RDQH5-250M(H)/4P | 382 | 209 | 169 |
RDQH5-400L/3P | 490 | 309 | 215 |
RDQH5-400L/4P | 539.5 | 309 | 215 |
RDQH5-630L/3P | 568 | 328 | 216.5 |
RDQH5-630L/4P | 626 | 328 | 216.5 |