RDQH switch transfer otomatis ditrapake kanggo sistem daya AC50Hz, voltase operasi dirating 380V, dirating operasi saiki 10A kanggo 1600A lt nransfer sirkuit antarane loro sumber daya sirkuit miturut kabutuhan. Prodhuk iki nduweni pangayoman marang kakehan, short-circuit, kurang voltase, lan uga nduweni proteksi geni, loro break sirkuit lan output nggawe fungsi sinyal.
Kondisi operasi normal lan kondisi instalasi:
1. Ketinggian lokasi instalasi ngirim ora ngluwihi 2000m.3.2 suhu sekitar ora ngluwihi +40'C, nanging ora luwih murah tinimbang 5'C. Suhu rata-rata saben dina ora ngluwihi + 35°C
2. Kelembapan: Kelembapan relatif ora luwih saka 50% nalika suhu +40C, lan kelembapan sing luwih dhuwur ditampa yen suhu luwih murah.3.4 Tingkat polusi:3
3.Lokasi instalasi ora kena pengaruh cuaca lan impact. Terminal ndhuwur nyambungake sisih daya, terminal ngisor nyambungake sisih beban. sudut miring karo bidang vertikal ora ngluwihi 5 ° C.
4. Jinis instalasi: lll.
5. Medan Magnetik njaba saka panggonan instalasi toko ora ngluwihi 5 kaping Magnetik bumi ing sembarang arah
| Paramèter | |||||
| 4.1 Parameter teknis utama ndeleng Tabel 1. | |||||
| Tabel 1 | |||||
| Parameter kinerja produk | |||||
| Standar | IECL00947-6-1 | ||||
| Tipe ATSE | Tipe CB | ||||
| Jinis panggunaan | AC-33iB | ||||
| Rated voltase operasi Ue | AC380V-400V | ||||
| Dirating frekuensi operasi | 50Hz | ||||
| ngalih voltase kontrol | AC23OVAC400V | ||||
| Tegangan isolasi Rated Ui | AC690V | ||||
| Wektu tumindak transfer mini | <3s | ||||
| urip | urip listrik | <400A | 1500 kaping | ≥400A | 1000 kaping |
| urip mekanik | 4500 kaping | 3000 kaping | |||
| 4.2 Spesifikasi ndeleng Tabel 2 | |||||
| Tabel 2 | |||||
| Spesifikasi | Ukuran pigura | Rated operasional saiki le(A) | Rated impuls short-circuit tahan voltase Uimp | Kapasitas putus hubung singkat Icn | |
| RDQH-63 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 8 kv | 5 kv | |
| RDQH-100 | 100 | 32, 40, 50, 63, 80, 100 | 8 kv | 10 kV | |
| RDQH-225 | 225 | 100, 125, 160, 180, 200, 225 | 8 kv | 10 kV | |
| RDQH-400 | 400 | 225, 250, 315, 350, 400 | 8 kv | 10 kV | |
| RDQH-630 | 630 | 400,500,630 | 8 kv | 13 kV | |
| RDQH-800 | 800 | 630,800 | 10 kV | 16kV | |
| RDQH-1250 | 1250 | 800, 1000,1250 | 12 kV | 25kV | |
| RDQH-1600 | 1600 | 1250, 1600 | 12 kV | 25kV | |
| 4.3 Fungsi pengontrol, deleng Tabel 3 | |||||
| Tabel 3 | |||||
| Model No. | RDOH ATSE Intelligent controller | ||||
| jinis instalasi | Jinis intergasi, jinis pesawat sing dipisahake | ||||
| jinis operasional | Manual, otomatis, mbukak pindho | ||||
| fungsi monitoring | phase-loss, voltase-loss, undervoltageovervoltage, manual, otomatis, pindho mbukak | ||||
| metode konversi | Ganti otomatis lan pemulihan otomatis, Ganti otomatis lan ora ana pemulihan otomatis.Siaga bebarengan, pilihan sing dioptimalake daya | ||||
| fungsi asli | proteksi geni breaking, generator sinyal wiwitan, tripping nguwatirake | ||||
| wektu tundha ngalih sumber daya | Os nganti 999s (nyetel dening pangguna) | ||||
| tundha pindho mbukak | 1 nganti 10 detik (diset dening pangguna) | ||||
| setelan jinis sistem | 1 #daya kutha 2#daya kutha, 1#daya kutha2#daya generator1#daya generator2#daya kutha | ||||